Performance
Frequency
Response (at 1
watt, 20 Hz - 20 kHz): ±0.25 dB.
Signal
to Noise Ratio
below rated power (20 Hz to 20 kHz): 105 dB A-weighted.
Total
Harmonic Distortion (THD)
at full rated power, from 20 Hz to 20 kHz: CTs 600< 0.1%.
Damping
Factor: 10 Hz to
100 Hz: > 3000.
Crosstalk
(below rated
power, 20 Hz to 1 kHz): > 80 dB.
Common
Mode Rejection (CMR)
(20 Hz to 1 kHz): 50 dB.
DC
Output Offset:
< 2 mV.
Input
Impedance
(nominal): 10 kilohms balanced, 5 kilohms unbalanced.
Maximum
Input Level: +20
dBu before input compression, +32 dBu absolute maximum.
Load
Impedance (Note:
Safe with all types of loads):
- CTs
600: Stereo: 2/4/8/16 ohms, 70V.“ Bridge Mono: 4/8/16 ohms,
140V.““
Voltage
Gain (at maximum
level setting):
8/4
ohm operation, 1.4V sensitivity
CTs 600 35:1 (31 dB)
26 dB: 20:1 (26 dB).
70V operation, 1.4V sensitivity or 100V operation, 2.0V sensitivity: 50:1
(34 dB).
Required
AC Mains (+15%,
–25%):
120V/60 Hz, 230V/50 Hz.
Power
Draw at Idle
(120VAC mains):
CTs 600: 24W (standby mode)“
Cooling:
Continuously
variable speed forced air, front-to-back airflow.
Dimensions:
19 in. (48.3 cm)
W x 3.5 in. (8.9 cm) H x 14.25 in. (36.2 cm) D.
Weight:
Net, Shipping
CTs 600: 27.7 lb
Front
Panel Controls and Indicators
Bridge
Mode Indicator:
Yellow LED illuminates when the rear-panel Mode Switch is set to the
“Bridge” position.
Ready
Indicator: Green
LED, one per channel, illuminates when the channel is initialized and
ready to produce audio output. Indicator is off when PIP puts the
amplifier in standby mode via the IQ system.
Signal
Indicators: Three
green LEDs per channel indicate the amplifier’s input and output signal
levels.
Signal:
input signal is above –40 dBu.“–20 dB: amplifier output is 20 dB
below clipping.“–10 dB: amplifier output is 10 dB below“clipping.
Clip
Indicator: Red
LED, one per channel, illuminates when the channel’s output signal
reaches the onset of audible clipping. The Clip Indicator also will
illuminate during Thermal Level Control (TLC) limiting or when the input
compressor/limiter is protecting the amplifier from input overload.
Thermal
Indicator: Red
LED, one per channel, illuminates when the channel has shut down, or is
very near shutting down, due to thermal stress or overload.
Fault
Indicator: Red
LED, one per channel, flashes when the amplifier output channel has
stopped operating.
|
Data
Indicator: Yellow
LED indicates IQ Loop data activity (if the amplifier is equipped with an
IQ-PIP2 module, and connected to an IQ Loop).
Power
Indicator: Blue
LED indicates amplifier has been turned on and AC power is available. The
LED will flash when the AC line voltage is 15% above or 25% below the
nominal rated value.
Cooling
Vents:
Front-to-rear forced airflow.
Power
Switch: Push-on /
push-off switch.
Back
Panel Controls and Connectors
Power
Cord Connector:
Standard 15 amp IEC inlet. Voltage is indicated above IEC inlet.
Reset
Switch: Resets
the circuit breaker that protects the power supply.
Speaker
Connectors: One
four-pole touch-proof terminal strip. Accepts up to 10 AWG terminal forks.
Input
Connectors:
Balaced 3-pin terminal block connectors, one per channel, on the standard
PIP2-BBY module.
Channel
Level Control:
One 21-position detented rotary attenuator per channel, ranging from minus
infinity (–70 dB) to 0 dB gain.
Mode
Switch: Two-position
switch is used to select the amplifier’s mode of operation: Dual or
Bridge-Mono.
Highpass
Filter: One
3-position switch per channel selects between OFF, 35Hz and 70Hz 3rd-order
filters.
“Y”
Input Switch: When
set to ON, this switch parallels the input signals of the two channels,
for use when the input signal is mono. Also can be used to daisy-chain the
signal to another amplifier.
Ventilation
Grille:
Front-to-rear forced airflow.
Options
PIP2
modules, including the PIP-Lite, PIP-USP3, and PIP-USP3/CN.
Protection
Systems
Thermal
Level Control (TLC): If
an amplifier channel starts to overheat, the TLC system will engage the
input compressor. By compressing the input, the amplifier will not
generate as much heat and will have a chance to cool down.
Junction
Temperature Simulation (JTS):
In the CTs 600, if excess power is demanded, JTS circuitry limits the
drive level of the output devices to a safe range, preventing damage.
Fault:
The amplifier will light the Fault LED if the amplifier output stage stops
operating.
AC
Under/Over Voltage Protection: If
the AC line voltage drops below 25% or rises above 15% of the nominal
operating voltage of the amplifier, the amplifier’s power supply turns
off and the blue Power LED flashes. The amplifier will turn back on when
the AC line voltage returns to safe operating levels.
Circuit
Breaker: This
breaker protects the amplifier from excessive AC current draw.
DC
Output Servo: The
output servo circuit protects your drivers by eliminating DC offset, even
in the presence of very large asymmetrical signals.
Inrush
Limiting: A
soft-start circuit in the power supply minimizes the amplifier’s current
draw during power-on.
Variable-speed
Fan: Two
continuously variable speed fans direct the airflow through the amplifier
for cooling.
|